A2LA accredited ISO/IEC 17025:2017 calibration · NIST traceableCalibration due? Book a recalibration · Distributors worldwide
Home / Products / PRX-301

PRX-301 Proximity Probe TesterStandalone automated DC linearity testing, no AT2040 needed

The PRX-301 is the PRX-300 with its own driver supply and voltage measurement built in. Clamp the probe, connect the driver and run the test from a Windows PC. It moves a 4140 steel target through the probe's range, records every point and judges every 10 mil segment against API 670 limits.

Built-in −24 V driver supplyBuilt-in DC voltage input0–90 mil · 10 mil steps5–19 mm probe bodiesPC controlled
Agate automated DC proximity probe tester with a probe clamped in the holder facing the 4140 steel target (PRX-300 shown; the PRX-301 has a taller controller housing)

Everything the test needs, in one case

Powers the driver

A built-in −24 V supply powers the proximity driver through the driver cable. No bench supply to set up.

Reads the output

A built-in isolated DC voltage input reads the driver output at every point. No external multimeter.

Every segment judged

Each 10 mil segment ISF, the average ISF and the DSL are checked against your limits, so a good average can't hide a bad segment.

How a test runs

The probe stays fixed in its holder. The target moves in exact 10 mil steps while the PRX-301 powers the driver and records its output. A test takes about 3 minutes.

  1. HomeThe target goes to its home reference before every test.
  2. Find the probeThe target travels in and settles where the driver output is −1.000 V. This is 0 mil.
  3. SweepTen points 10 mil apart. At each one the target settles, waits 10 s and averages 20 readings.
  4. JudgeEvery segment ISF, the average ISF and the DSL against your limits.
  5. Check and saveThe target returns home and checks for screw slip, then the result is saved on the PC.

Specifications

Range0–90 mil in 10 mil steps (10 points), starting at the −1 V reference gap
Driver supplyBuilt-in −24 V DC output (MS3102A10SL-3P, pin A)
Voltage measurementBuilt-in isolated DC voltage input (MS3102A10SL-3P, pin C)
ProbesAdjustable V-block clamp for probe bodies 5 to 19 mm (3/16 to 3/4 in), metric or imperial, threaded or smooth
JudgedEvery 10 mil segment ISF, average ISF (10–90 mil) and DSL. Presets: 1–5 m systems ISF ±5 %, DSL ±1 mil; 9 m systems ISF ±6.5 %, DSL ±1.5 mil. Nominal ISF and limits adjustable
RepeatabilitySegment ISF ±0.75 % (95 %) with the probe re-seated; average ISF ±0.17 %
ProtectionHomes before every test, travel limits in the motion controller, screw slip check after every test (more than 0.5 mil fails the result)
TargetAISI 4140 steel, 1/4-28 stud. Other materials on request
HostWindows PC, USB serial cable C01 (USB-A to M8), 115200 baud
Power12 V USB-C Power Delivery supply (supplied)
In the casePRX-301 tester with probe holder, 12 V USB-C supply, 4140 steel target, serial cable C01, driver cable C02 (1.5 m) and calibration certificate, in a Pelican 1400 case with custom foam

Repeatability measured by Agate on one 8 mm probe system. Specifications subject to change. API 670 is a standard of the American Petroleum Institute; the PRX-301 is not certified or endorsed by API.

Download the PRX-300 / PRX-301 operator manual (PDF, 1 MB) →

PRX-300 or PRX-301?

Both use the same mechanism and run the same test. The difference is what powers the proximity driver and reads its output.

ComparePRX-300PRX-301
What it isMotion fixture for the AT2040. Cannot be used on its ownAll-in-one standalone tester. No AT2040 needed
Controlled fromAT2040 touchscreen (Prox DC Linearity screen)Windows PC
−24 V driver supplyFrom the AT2040 proximity driver power outputBuilt in, on the MS3102A10SL-3P driver connector
Driver output readingAT2040 DC inputBuilt-in isolated DC voltage input. No external DMM needed
Driver connectionDriver wired to the AT2040Driver cable C02 (1.5 m) to the −VT, COM and OUT terminals
Serial linkSame on both: M8 serial port and USB serial cable C01, to the AT2040 (PRX-300) or a PC (PRX-301)
ReportsStored on the AT2040; PDF or CSV export to USBSaved on the PC
Power12 V USB-C Power Delivery supply, supplied with both
Best forLabs that already own an AT2040Sites without an AT2040, or a dedicated probe test bench

Already have an AT2040? See the PRX-300, which runs the same test from the AT2040 touchscreen.

Spare cables and supply

PRX301-C02Driver cable: 3-pin MIL plug to driver terminals (−VT, COM, OUT), 1.5 m
PRX301-C01USB serial cable: USB-A to M8
PRX301-PSPower supply: 12 V USB-C PD charger

Questions

Do I need an AT2040 to use the PRX-301?

No. The PRX-301 has its own −24 V driver supply and DC voltage input, and runs from a Windows PC. If you already own an AT2040, the PRX-300 runs the same test from the AT2040 touchscreen.

Which probes does it test?

Eddy-current proximity probes with bodies from 5 mm to 19 mm (3/16 to 3/4 in) diameter, metric or imperial, threaded or smooth. The holder is an adjustable clamp, so any size in that range fits.

What does it measure?

It steps the gap from 0 to 90 mil in 10 mil steps and records the driver output at each point, then works out the incremental scale factor (ISF) of every 10 mil segment, the average ISF and the deviation from a straight line (DSL), and judges each one against your limits.

How is the proximity driver connected?

With the supplied driver cable C02, from the PRX-301's MS3102A10SL-3P connector to the driver's −VT, COM and OUT terminals. The PRX-301 powers the driver and reads its output on the same connector.

How long does a test take?

About 3 minutes, including homing, finding the −1 V start point, the 10-point sweep and the screw slip check.

Test probes without an AT2040

Tell us which probe systems you test and how many, and we'll quote the PRX-301 with lead time and shipping.

Request a quote WhatsApp +1 760-215-9670 Talk to an engineer
Scroll to Top